Precisio™ Software Release Notes
Versions
- 2.7.0.7 (September 29, 2026)
- 2.7 (August 14, 2026)
- 2.6.3.4 (July 9, 2026)
- 2.6.3.3 (July 3, 2026)
- 2.6.3.2 (June 12, 2026)
- 2.6.3.1 (April 16, 2026)
- 2.6.3 (March 16, 2026)
- 2.6.2.1 (March 11, 2026)
- 2.6.2 (December 23, 2025)
- 2.6.1 (September 15, 2025)
- 2.6.0.1 (August 19, 2025)
- 2.6 (July 7, 2025)
- 2.5.1.4 (March 13, 2026)
- 2.5.1.3 (December 12, 2025)
- 2.5.1.2 (October 2, 2025)
- 2.5.1.1 (August 12, 2025)
- 2.5.1 (July 19, 2025)
- 2.5.0.4 (April 24, 2025)
- 2.5.0.3 (April 4, 2025)
- 2.5.0.2 (March 26, 2025)
- 2.5 (March 21, 2025)
- 2.4.2.3 (March 13, 2026)
- 2.4.2.2 (June 20, 2025)
- 2.4.2 (January 22, 2025)
- 2.4.1.6 (January 17, 2025)
- 2.4.1.5 (December 9, 2024)
- 2.4.1.2 (September 17, 2024)
- 2.4.1.1 (July 29, 2024)
- 2.4.1 (June 21, 2024)
- 2.4.0 (March 21, 2024)
- 2.2.6.9 (April 25, 2024)
- 2.2.6.8 (November 15, 2023)
- 2.2.6.7 (September 27, 2023)
- 2.2.6.6 (August 24, 2023)
- 2.2.6 (July 4, 2023)
- 2.2.5.3 (April 11, 2023)
- 2.2.5 (February 21, 2023)
- 2.2.4.3 (January 19, 2023)
- 2.2.4 (October 5, 2022)
- 2.2.3 (August 18, 2022)
- 2.2.2 (August 5, 2022)
- 2.2.1 (July 17, 2022)
- 2.1.3 (May 13, 2022)
- 2.1.2 (February 17, 2022)
- 2.1.1 (February 4, 2022)
- 2.1.0 (January 24, 2022)
- 2.0.2 (December 22, 2021)
- 2.0.1 (December 10, 2021)
- 2.0.0 (November 30, 2021)
- 1.9.1 (October 20, 2021)
- 1.9.0 (September 2, 2021)
- 1.8.5 (May 04, 2021)
- 1.8.4 (April 14, 2021)
- 1.8.3 (December 10, 2020)
- 1.8.2 (September 22, 2020)
- 1.8.1 (July 24, 2020)
- 1.8.0 (May 26, 2020)
- 1.7.5 (November 28, 2019)
- 1.7.4 (October 25, 2019)
- 1.7.3 (August 9, 2019)
- 1.7.2 (March 7, 2019)
- 1.7.1 (February 19, 2019)
- 1.7.0 (October 31, 2018)
- 1.6.4 (July 12, 2018)
- 1.6.3 (May 18, 2018)
2.7.0.7 (September 29, 2026)
- [SEM/EA] Fixes a UI refresh issue that could interfere with setting the focal plane (WD) in certain cases.
2.7 (August 14, 2026)
New features:
- [SEM/EA]
- Get faster results with a completely redesigned user interface that puts the most-used SEM functions at your fingertips.
- Interact directly with images to quickly define your scan region and speed.
- Visualize multiple channels simultaneously with live synchronized imaging of multi-channel EFA signals.
- Switch between Ex Situ and In Situ signal amplification in one click and customize the image layout to your preference.
- Accelerate defect localization through color-coding and selective source mixing.
- Ensure reproducible results by saving all acquisition parameters with your SEM and EA images, enabling post-processing and quantitative electrical analysis.
Improvements:
2.6.3.4 (July 9, 2026)
- [Probing]
- Fixes layout handling of contact tests to ensure elements fit the container.
- Fixes measurements hanging indefinitely when connected via GPIB to Keithley 4200A-SCS (requires Clarius+ v1.7 or above).
2.6.3.2 (June 12, 2026)
- [Robots] Fixes an issue where the sub-stage homing procedure could become stuck.
2.6.3.2 (June 12, 2026)
2.6.3.1 (April 16, 2026)
[Data Management & Reporting] Fixes an issue that prevented measurement graph images from being saved correctly.
[Probing] Resolves an issue that prevented certain models of Keithley TSP® compatible SMU instruments from initializing correctly.
2.6.3 (March 16, 2026)
New features:
Improvements:
[Data Management & Reporting] Fixes an issue where graph zooming did not work correctly with logarithmic axes.
[Probing Automation]
- Fixes an issue where automated routines could start at a mask marked as not visitable.
- Fixes an issue that would sometimes block Precisio when creating a new target layout.
[Robots]
- Fixes an initialization issue with scanning values that could lead to unexpected robot movement if Precisio starts while the Motion Controller is already applying voltage to the actuators.
- Improves sub-stage shutdown process that would sometimes prevent the software to close.
- Fixes an issue when enabling the Advanced Control Mode with a disconnected sub-stage.
[Core] Improves user experience with faster tooltips responsiveness.
[Stage] Fixes an issue not properly setting Z axis limits of the motorized stage.
[SEM/EA] Fixes incorrect channel numbering for an EFA system with a nanoprobing platform for 4 robots and ex situ signal amplification.
2.6.2.1 (March 11, 2026)
- [Robots] Fixes an error that occurred when using the step-by-step (Pulse) mode with syDrive-based systems.
2.6.2 (December 23, 2025)
New features:
- [Probe Cleaning SPA] The optional Probe Cleaning SPA extension is now available in the Probing module for NANO systems that support remote control of the Keithley 4200A‑SCS. It provides an intuitive workflow to remove thin contamination layers from probe tips that can compromise electrical contact. Operators can start cleaning on demand and receive guidance for choosing optimal electrical parameters to evaporate contaminants efficiently.
Improvements:
2.6.1 (September 15, 2025)
New features:
- [Probing Automation]
- The Probing Automation module for Precisio™ is now available for NANO systems equipped with EFA for SEM and an Encoded Sample Positioning XYZ Sub-Stage. Users can easily create, customize, and run automated electrical probing routines at multiple, repeatable sample positions arranged in grid patterns.
- Allows users to fine-tune probe positions before each measurement.
- Introduces a trajectory optimizer that reduces stage movement when traversing selected target locations.
Improvements:
- [Robots]
- Enables user to configure custom one-click lowering and raising distances for the sub-stage.
- Clarifies messages regarding maintaining or resetting the sub-stage position when exiting Precisio.
2.6.0.1 (August 19, 2025)
[Probing]
- Resolves an issue that prevented live plotting from functioning with certain versions of the Keysight B1500.
[SEM/EA]
- Fixes a UI issue where the value displayed as 0 after setting HV.
- Corrects the brightness slider range.
2.6 (July 7, 2025)
New features:
[Robots]
- Introduces support for the new Imina Technologies Encoded Sample Positioning XYZ Sub-Stage SS312, featuring enhanced UI controls to:
- Move the sub-stage precisely to absolute target locations.
- Lower or raise the sample by predefined distances.
- Save positions and return to them with a single mouse click.
- Adds click-and-move functionality for NANO systems equipped with EFA, enabling users to center the sample in the SEM image by simply clicking on the desired location.
[SEM/EA]
- Enables precise distance measurements directly on SEM images.
- Introduces annotation layers that can be overlaid on SEM images.
2.5.1.4 (March 13, 2026)
- [Robots] Fixes an initialization issue with scanning values that could lead to unexpected robot movement if Precisio starts while the Motion Controller is already applying voltage to the actuators.
2.5.1.3 (December 12, 2025)
- [Core] Improves startup logging of Precisio.
2.5.1.2 (October 2, 2025)
- [Probing Automation]
- Resolves a connectivity issue that could cause the Keithley 4200A instrument to disconnect unexpectedly during automated probing routines.
- Allows automated routines to be restarted from any selected probing location, skipping locations with lower IDs.
2.5.1.1 (August 12, 2025)
- [Probing Automation]
- Fixes an issue where automated routines could become stuck if the stage target position was not different from the current position.
2.5.1 (July 19, 2025)
New features:
- [Probing Automation] The powerful Probing Automation module for the Precisio™ software suite is designed to streamline and accelerate electrical probing workflows. Effortlessly create, customize, and execute automated routines for probing at multiple, repeatable sample positions arranged in grid patterns. This module integrates with MICRO systems featuring an optical microscope and a motorized stage.
Improvements:
[SEM/EA]
- The EFA user interface now allows switching the sample bias between internal ground and external bias.
- Beam current (BC) can now be set directly from Precisio as a SEM parameter. (Requires EMGateway v2.2.4.1).
- The UI now automatically selects the EFA multi-channel when the probing function changes, improving workflow efficiency.
[Robots]
- Communication with the sub-stage is now faster and more reliable.
- Sub-stage position control is safer thanks to new hardware-level locking mechanisms.
[Probing] Exported measurement graphs now consistently reflect the selected graph zoom level.
[Data Management & Reporting] Resolves a UI memory leak that could cause Precisio to crash during extended use.
[Microscope]
- Fixed an issue where robot movement could not be stopped when the Distance Measurement wizard was active.
- The click-and-move button no longer appears on saved microscope images.
[Stage] Fixed an issue that prevented the motorized stage from closing when its controller was physically disconnected.
[Core] Enhanced software logging and reporting for improved traceability and diagnostics.
2.5.0.4 (April 24, 2025)
- [Robots] Fixes an issue that occurred in some cases with Assisted Descent enabled that prevented the robot from stopping a Z move.
2.5.0.3 (April 4, 2025)
- [SEM/EA] Fixes an issue with initializing the EFA system on a system without the EFA44 configuration.
2.5.0.2 (March 26, 2025)
- [Robots] Fixes an issue that prevented a sub-stage movement in Z from stopping.
2.5 (March 21, 2025)
New features:
[SEM/EA]
- Adds support for the new Advanced EFA (EFA44) configuration that can equip Imina Technologies nanoprobing platforms with 4 direct probing channels and 4 switchable EFA channels featuring high-sensitivity in situ signal amplification. This configuration allows the user to effortlessly switch nanoprobe functions between EFA techniques (EBIC, EBAC/RCI, EBIRCh) and direct probing with just a few clicks.
- Adds support for the new generation of EFA system from Point Electronic GmbH (V2).
[Robots] Adds support for the new generation of Imina Technologies Sample Positioning XYZ Sub-Stage SS302.
[Stage] Adds click-and-move functionality to the MICRO probe station that allows the user to simply click on the microscope image to center the wafer in the field of view.
Improvements:
[Microscope] Speeds up the microscope image calibration process at different magnifications by reducing the number of calibration points required.
[SEM/EA] Makes it easier to switch EFA signal amplifiers between Ex Situ and In Situ.
[Probing]
- Improves the user interface of the contact verification step of the probing workflow for 1 or 2 contact test cases.
- Improves sorting of measurement recipes and saving preferences in user settings.
- Fixes graph zoom selection not capturing mouse leaving the graph.
[Robots] Show stepping speed indexes in UI.
2.4.2.3 (March 13, 2026)
- [Robots] Fixes an initialization issue with scanning values that could lead to unexpected robot movement if Precisio starts while the Motion Controller is already applying voltage to the actuators.
2.4.2.2 (June 20, 2025)
- [Probing] Resolves a multithreading issue that could cause errors when accessing measurement graph data.
2.4.2 (January 22, 2025)
New features:
[Probing] The new KULT Measurement Recipe software add-on significantly expands the measurement capabilities of the Precisio Probing module. This new feature enables remote operation of a Keithley User Test Module (UTM) on the Keithley 4200A-SCS, allowing users to seamlessly retrieve measurement data within the Precisio Data Management & Reporting module. With this add-on, both pulse and CV measurements can now be directly integrated into the Precisio test workflow, streamlining the testing process and improving overall efficiency.
[Probing] Adds the capability to zoom in on specific areas of the measurement graph for enhanced data analysis.
Improvements:
[Probing]
- Enhances the robustness of custom curves based on mathematical expressions and improves the user interface for creating new measurement recipes.
- Fixes an issue that caused the selected measurement recipe to become invalid when the connected hardware was changed.
- Improves the handling of incorrect user configurations of the Keithley 4200A-CVIV Multi-Switch.
[Data Management & Reporting] Retains the column order in the measurement table based on user preferences.
[SEM/EA]
- Improves the clarity of SEM parameter values.
- Fixes an issue that prevented customizing saved image file names.
[Microscope] Improves the hot plugging functionality of the microscope camera.
[Core] Fixes an issue with handling special characters that caused problems when saving measurement files.
2.4.1.6 (January 17, 2025)
- [Probing] Fixes compatibility issues with old generation of Keithley 4200-SCS (Software version: V9.0).
2.4.1.5 (December 9, 2024)
- [Probing] Fixes an issue that prevented some Keithley SMUs compatible with TSP® to be detected.
2.4.1.2 (September 17, 2024)
- [Probing] Adds support for the Keithley 4200A-CVIV Multi-Switch.
2.4.1.1 (July 29, 2024)
- [SDK] Add support for the NANO+ technology.
2.4.1 (June 21, 2024)
- [Robots] Adds support for the new NANO+ technology which greatly simplifies the probe landing procedure by extending 10x the robot's vertical range of motion in fine mode to 15 µm at the probe tip.
- [Data Management & Reporting] Improves the readability of electrical measurement graphs with new features that allow legends to be better placed and visibility managed.
- [Data Management & Reporting] Improves the reading of measurement graphs generated using similar recipe.
- [Data Management & Reporting] Saves the sample temperature with electrical measurements in the database (Thermal module is required.)
- [Data Management & Reporting] Improves database password management.
- [Probing] Speeds up measurement graph plotting.
- [Stage] Adds the keyboard as an interface for controlling the movements of the motorized stage.
- [SEM/EA] Fixes an issue that sometimes prevented brightness and contrast values in the RCI technique from being set correctly.
2.4.0 (March 21, 2024)
- [Thermal] The new Thermal module of the Precisio™ software suite is the user interface for the Thermal Stage Kit TSK1 of Imina Technologies NANO Solutions. In a user-friendly environment, the heating and cooling temperature of a sample can easily be adjusted, and thermal data can be viewed and recorded in real time.
2.2.6.9 (April 25, 2024)
- [Probing] Improves timeout handling and command sending for old versions of Keysight B1500 firmware (A.06.01.2015.1112).
- [Core] Fixes an issue that generated a file conversion notification when starting Precisio.
2.2.6.8 (November 15, 2023)
- [Robots] Fixes an incorrect user notification related to hardware compatibility of the Motion Controller.
2.2.6.7 (September 27, 2023)
- [Probing] Fixes an issue that caused the software to crash for certain recipe configurations that included simultaneous sweeps (specific to Keysight B1500).
2.2.6.6 (August 24, 2023)
- [SEM/EA] Fixes an issue that limited the brightness adjustment range on the RCI technique with in situ hardware amplification.
- [SEM/EA] Fixes an issue that kept the voltage bias on after stopping the EBIRCH technique.
2.2.6 (July 4, 2023)
- [SEM/EA] Recorded images can now also be saved as PNG files with the SEM parameters displayed in a bottom banner.
- [Data Management & Reporting] Word and PowerPoint report templates are included in the module.
- [Microscope] Improves user experience regarding settings and interactions with annotation layers overlaid on the microscope image stream.
- [Microscope] Improves the wizard to facilitate the process of optical microscope and motorized zoom calibration and verification.
- [Stage] Improves the wizard to facilitate the process of motorized stage calibration and verification.
- [Robots] Upgrades the USB library used to communicate with syDrive based systems.
- [Probing] Fixes an issue that prevented the Probe Cleaning module to start.
- [Data Management & Reporting] Fixes an issue with plotting extreme measurement values that sometimes caused the graph display to hang.
- [SEM/EA] Fixes an issue with initializing some gain and brightness values limiting the range available for image adjustments.
- [Stage] Fixes an issue that caused joystick communication latency.
- [Core] Fixes an issue that sometimes hid a folder browse dialog from the user and forced Precisio to restart.
2.2.5.3 (April 11, 2023)
- [Probing] Fixes an issue that fixed the current measurement range based on a set integration time type (specific to Keysight B1500).
2.2.5 (February 21, 2023)
New features:
- [Robots] Adds assistance to the operator for the descent of a probe on a sample.
- [Probing] Adds measurement names customization.
- [Data Management & Reporting] Adds functions for setting the limits of the axes of the measurement graph.
- [Data Management & Reporting] Adds report duplicate feature.
- [SEM/EA] Adds image files recording settings customization.
- [SEM/EA] Adds minimum and maximum bias voltage limitation for EBIC and EBIRCH techniques.
Improvements:
- [Probing] Improves robustness of measurement graphs to outliers.
- [Data Management & Reporting] Fixes an issue that prevents importing password-protected measurements into the database.
- [Data Management & Reporting] Fixes an issue that sometimes generates an exception when importing a recipe from a measurement.
- [Data Management & Reporting] Improves customization of measurements table display and related user settings.
- [Data Management & Reporting] Improves report management user experience.
- [Microscope] Fixes a communication issue with the motorized zoom controller that sometimes prevents the Motion Controller from connecting.
- [Robots] Platform product names are used in the configuration instead of generic descriptions.
2.2.4.3 (January 19, 2023)
- [Probing] Supports measurement recipes with simultaneous current and voltage sweeps across multiple terminals on Keysight B1500.
- [Probing] Improves the use of integration times to speed-up measurements with the Keysight B1500.
- [Probing] Fixes an issue that sometimes freezes the UI when running contact verification tests.
- [Probing] Fixes the issue of the measurement which stops when the window loses focus.
- [SEM/EA] Fixes the issue that was hiding the Release Scan Control button.
2.2.4 (October 5, 2022)
- [SEM/EA] Improves controls to allow more precise tuning of voltage bias and compensation current.
- [SEM/EA] Improves communication with the SEM and the SEM parameters adjustment.
- [Microscope] Improves user experience and stability of image calibrations and distance measurements.
- [Robots] Fixes a display issue with the platform wiring settings dialog.
- [Stage] Fixes an issue where the joystick may cause the stage homing procedure to stop.
- [Data Management & Reporting] Fixes an issue that was causing some recipe information not to be correctly loaded on a measurement.
- [Core] Fixes an issue where dialog boxes are sometimes hidden by other windows.
2.2.3 (August 18, 2022)
- [Microscope] Simplifies image calibration and calibration management.
- [Microscope] Fixes issues that prevented motorized zoom from reaching certain target values.
2.2.2 (August 5, 2022)
- [Probing] Supports measurement recipes with simultaneous voltage sweeps across multiple terminals on Keithley 4200-SCS.
2.2.1 (July 17, 2022)
- [SEM/EA] Improves user experience of SEM settings (HV, Mag and WD) and display of center cross overlay on images.
- [SEM/EA] Fixes a compatibility issue with Point Electronic EFA system configuration files.
- [Data Management & Reporting] Version management of measurement databases has been improved and migration information has been clarified for the user.
- [Probing] Fixes the issue of the contact test configuration window not being sized to fit the content in some cases.
- [Robots] Fixes the issue of the miBot selector being reset or incorrectly set during certain usage workflows.
- [Robots] Fixes issue with robot movement directions dialog not opening in some cases.
- [Stage] Improves the handling of motorized stage limit parameterization and fixes the issue of limits not being validated in some cases.
- [Stage] Improves connection speed to the motorized stage controller.
- [Microscope] Fixes issue preventing showing/hiding of the distance measurements image overlay.
- [Core] Precisio now relies on the latest Microsoft .NET Framework 4.8.
2.1.3 (May 13, 2022)
- [SEM/EA] Fixes an issue with TIFF image file format.
- [Robots] Fixes issues with the wiring configuration and other minor issues with UI.
- [Microscope] Fixes update of UI at initialization.
2.1.2 (February 17, 2022)
- [Robots] Fixes incorrect user warnings due to different Motion Controller MC410/20 firmware versions.
2.1.1 (February 4, 2022)
- [Robots] Adds possibility to control the robots from the user interface (mouse) and keyboard.
- [Microscope] The size of the scale bar and dimensional measurements displayed on the microscope image is now automatically updated according to the zoom level.
2.1.0 (January 24, 2022)
- [SEM/EA] Updates compatibility with the new in-situ signal amplification hardware module.
- [Robots] Automates installation of the Motion Controller MC410/20 USB drivers during Precisio installation.
- [Robots] Fixes some issues with sub-stage movement being controlled with the USB control pad.
- [Probing] Fixes issues related to opening the data folder in some specific cases.
- [Stage] Improves communication speed with the motorized stage controller of the microprobing platform.
2.0.2 (December 22, 2021)
- [Probing] Fixes support of SMU for the Keithley 4200 running older KXCI version 7.
2.0.1 (December 10, 2021)
- [Robots] Fixes minor user interface bugs for systems running syDrive controllers.
2.0.0 (November 30, 2021)
- [Core] Hardware device management has been simplified. Most devices are now detected automatically and can be started while Precisio is running.
- [Core] User notifications have been redesigned to make them more useful while being less intrusive.
- [Probing] Adds support for Keithley Source Measure Unit (SMU) instruments compatible with Test Script Processor (TSP®). Multi-channel parallel testing can also be performed with instruments supporting Keithley TSP-Link® expansion technology.
- [Robots] Several bug fix and minor improvements of user interface.
1.9.1 (October 20, 2021)
- [SEM/EA] An SEM can now be controlled by Precisio from a remote computer on the same local network.
1.9.0 (September 02, 2021)
- [SEM/EA] The new module SEM and Electrical Analysis is added to the Precisio™ software suite. It centralizes in a single software application the control of the scanning electron microscope as well as the new generation of electrical analysis equipment. Techniques such as EBIC, EBIRCH, EBAC, and RCI are easily configurable from a streamlined user interface, greatly simplifying failure analysis and defect localization for semiconductor devices.
- [Probing] Adds support for the new optional Probe Cleaning module. This allows you to remove eventual oxidation and particles from the probe tips to get the best electrical contact with the device under test.
- [Robots] Improves communication speed with Motion Controller MC410/20.
- [Core] Fixes minor issues with license activation on Microsoft Windows 7.
1.8.5 (May 04, 2021)
- [SDK] Adds support for the new Motion Controller MC410/20.
- [Core] Fixes issues with filenames with non-English characters.
1.8.4 (April 14, 2021)
- [Core] Software updates. Users are now automatically notified at Precisio startup of the availability of new software versions. (The computer needs to be connected to the internet.) If available, the software can then be downloaded and installed automatically.
- [Core] When a new version of Precisio is installed, the user settings of the previous version are now automatically used.
- [Core] After a new installation of Precisio, the license can now be automatically activated by a click of button at the start of the application. (The computer needs to be connected to the internet.)
1.8.3 (December 10, 2020)
- [Robots] The experienced user can now have more control over the speed and motion positioning resolution of his robots, directly from the Robots Control panel. The advanced control mode can quickly be enabled from the settings dialog.
- [Robots] Single / all robots settings. Sometimes it is easier to apply the same set of motion parameters to all robots, but sometimes it does not make sense. Now it is possible to decide for every speed mode if the parameter applies to the active robot or to all robots.
1.8.2 (September 22, 2020)
- [Core] Fixes some issues in the license activation process.
1.8.1 (July 24, 2020)
- [Robots] Adds support for the new Motion Controller MC410/20.
1.8.0 (May 26, 2020)
- [Data Management & Reporting] The new Data Management & Reporting module is added to the Precisio™ software suite. It completes the nanoprobing workflow and provides the means to manage all electrical measurements across time, per samples and measurement recipes. Tools to compare plotted curves side by side, comment and export results in office file formats are also included. The module has an offline mode which allows data to be processed without connected devices, for example at the end of a nanoprobing measurement session. Data are securely managed from Precisio with encryption and backup capabilities.
1.7.5 (November 28, 2019)
- [Probing] Adds live plotting of measurement data during acquisition.
- [Probing] Fixes compatibility issue with Keithley 4200A-SCS Clarius+ v1.7.
1.7.4 (October 25, 2019)
- [Probing] Adds support for the Keysight B1500A parameter analyzer.
1.7.3 (August 9, 2019)
- [Probing] Adds templates test recipes and simplify the workflow to create and import new ones.
- [Probing] Adds multiple charts generation per measurement, including custom curves based on mathematical expressions.
- [Robots] Adds support for the Sample Positioning XYZ Sub-Stage embedded into the nanoprobing platform.
1.7.2 (March 7, 2019)
- [Robots] Fixes an issue that sometimes caused the control pad to stop responding.
1.7.1 (February 19, 2019)
- [Probing] Adds support for the new Active Sample Holder option of the nanoprobing platforms.
1.7.0 (October 31, 2018)
- [Robots] The user experience is greatly enhanced with the introduction of a new simplified interface to control the robots. The compact window provides a clear overview on all robots, their position on the platform, and their motion modes.
- [Robots] Fixes the issue that appeared when several control pads where connected to the computer.
1.6.4 (July 12, 2018)
- [Probing] Adds Ethernet communication support for the Keithley 4200A SCS instrument.
- [Probing] Improves configuration and readability of plotted curves.
- [Probing] Improves export of measurements raw data and graphs.
1.6.3 (May 18, 2018)
- [Probing] The new Probing module is added to the Precisio™ software suite. The step-by-step workflow helps the operator to configure the system, land the probe tips on the device under test, and acquire measurement data. The module thus provides an intuitive interface to remotely control the parameter analyzer to which the robot mounted probe tips are connected (currently supports the Keithley 4200A SCS Parameter Analyzer).